Gas-Fired Unit Heater - 200,000 BTU/Hour (Input), 164,000 BTU/Hour (Output)
SKU
1641059
SKU: 1641059
Brand: MODINE
Item Description:
25-5/8'' x 34-3/4'' x 40-1/4'', 115 V, 1-Phase, 5.15 A, 200000/164000 BTU/Hr, 2870 CFM, Gray/Green, Baked Polyester Powder Coated, 20 Gauge Aluminized Steel Cabinet, Thermostat Control, Corrosion Resistant, Gas-Fired Unit Heater
$1,691.63/each
In stock
MODINE 43714 PDP200AE0130SBAN BTU 200,000 GAS UNIT HEATER
Product Info
Features/Benefits :
The Main Gas Valve is Factory Installed on the Unit Heater Gas Train; The Main Gas Valve Provides the Pilot, Regulator, Main Gas and Manual Shut-Off Functions; The Ignition Controller is Factory Installed on the Back of the Unit Heater with the Spark Igniter and Sensor Located on the Burner; For Both Natural and Propane Gas Units, the Ignition Controller is 100 Percent Shut-Off with Continuous Retry; On a Call for Heat, the System will Attempt to Light the Pilot for 70 Seconds if the Pilot is Not Sensed for any Reason, the Ignition Control will Wait for Approximately Six Minutes with the Combination Gas Control Closed and No Spark; After Six Minutes, the Cycle will Begin Again; After Three Cycles, Some Ignition Controllers Lockout for Approximately One Hour before the Cycle Begins Again; This will Continue Indefinitely Until the Pilot Flame is Sensed or Power is Interrupted to the System; The Time Delay Relay is Factory Installed in Electrical Junction Box; The Time Delay Relay Allows the Gas Controls to Operate for Approximately 30 to 90 Seconds before the Blower Starts; This Allows the Heat Exchanger a Warm up Period So that the Initial Delivered Air is Not Cool; The Time Delay Relay also Keeps the Motor Running for Approximately 30 to 90 Seconds after the Call for Heat has Been Satisfied to Remove the Residual Heat from the Heat Exchanger; The Low Voltage Terminal Board is Located in Electrical Junction Box; The Terminal Board is Labeled to Match the Electrical Wiring Diagram Provided with the Unit; The Automatic Reset High Limit Switch is Factory Installed on the Side Of the Unit Heater; If the Limit Temperature is Exceeded, the Gas Controls are De-Energized Until the Switch is Cooled; A Automatic Reset Vent Pressure Switch is Supplied on All Power Vented Unit Heaters to Prevent Operation Of the Main Burner in the Event there is Restricted Venting Of Flue Products; This Restriction May Occur Due to an Improper Vent Diameter, Long Vent Runs, Un-Approved Vent Term
Detailed Description | Gas-Fired Unit Heater; Type Corrosion Resistant; Voltage Rating 115 Volt at 60 Hertz; Current Rating 5.15 Amp; Number of Phases 1; Capacity 200000 BTU/Hour (Input), 164000 BTU/Hour (Output); Heating Element Aluminized Steel; Control Type Thermostat; |
---|---|
Size | 25-5/8'' x 34-3/4'' x 40-1/4'' |
Length | 43.75 in |
Shipping weight | 239 |
Manufacturer Name | MODINE |
Features/Benefits | The Main Gas Valve is Factory Installed on the Unit Heater Gas Train; The Main Gas Valve Provides the Pilot, Regulator, Main Gas and Manual Shut-Off Functions; The Ignition Controller is Factory Installed on the Back of the Unit Heater with the Spark Igniter and Sensor Located on the Burner; For Both Natural and Propane Gas Units, the Ignition Controller is 100 Percent Shut-Off with Continuous Retry; On a Call for Heat, the System will Attempt to Light the Pilot for 70 Seconds if the Pilot is Not Sensed for any Reason, the Ignition Control will Wait for Approximately Six Minutes with the Combination Gas Control Closed and No Spark; After Six Minutes, the Cycle will Begin Again; After Three Cycles, Some Ignition Controllers Lockout for Approximately One Hour before the Cycle Begins Again; This will Continue Indefinitely Until the Pilot Flame is Sensed or Power is Interrupted to the System; The Time Delay Relay is Factory Installed in Electrical Junction Box; The Time Delay Relay Allows the Gas Controls to Operate for Approximately 30 to 90 Seconds before the Blower Starts; This Allows the Heat Exchanger a Warm up Period So that the Initial Delivered Air is Not Cool; The Time Delay Relay also Keeps the Motor Running for Approximately 30 to 90 Seconds after the Call for Heat has Been Satisfied to Remove the Residual Heat from the Heat Exchanger; The Low Voltage Terminal Board is Located in Electrical Junction Box; The Terminal Board is Labeled to Match the Electrical Wiring Diagram Provided with the Unit; The Automatic Reset High Limit Switch is Factory Installed on the Side Of the Unit Heater; If the Limit Temperature is Exceeded, the Gas Controls are De-Energized Until the Switch is Cooled; A Automatic Reset Vent Pressure Switch is Supplied on All Power Vented Unit Heaters to Prevent Operation Of the Main Burner in the Event there is Restricted Venting Of Flue Products; This Restriction May Occur Due to an Improper Vent Diameter, Long Vent Runs, Un-Approved Vent Term |
Control Type | Thermostat |
Shop By Brand | MODINE |
Additional Information | Gas Type Natural Gas; Ignition Type Intermittent Pilot; Air Velocity 819 FPM; Thermal Efficiency 82 Percent; Air Temperature Rating 52 Deg F |
Application | Residential, Commerc |
BTU | 200,000 BTU/Hour (Input), 164, |
Finish | Gray/Green, Baked Polyester Po |
Manufacturer Part Number | PDP-200-A-E-01-30-S-B-A-N |
Short Description | 25-5/8'' x 34-3/4'' x 40-1/4'', 115 V, 1-Phase, 5.15 A, 200000/164000 BTU/Hr, 2870 CFM, Gray/Green, Baked Polyester Powder Coated, 20 Gauge Aluminized Steel Cabinet, Thermostat Control, Corrosion Resistant, Gas-Fired Unit Heater |
Product | Gas-Fired Unit Heater |
Series/Model | PDP |
Size A | 25-5/8 Inch Width x 34-3/ |
Type | Gas-Fired Unit Heater |
Manuals
No Manuals Available.
Replacement Parts
There are no replacement parts for this item.
Related Products
There are no related products for this item.